Picture | ES Part No. | Part No | Stock | Price | Datasheet | Pb Free | RoHS | Description | Temperature Measurement Range(MIN - MAX) | Measurement Accuracy | Thermal sensitivity(at Target Temperature) | Display Resolution | Instrument Type | Measurement Methods | Series | Include Accessories | Vendor |
0061-0489-4 | FLUKE53-2B | 2 | 19,052.80 | PB-Free | RoHS | Digital Thermometer Single Input with USB Record 60HZ with Data Logging,Contact Type J,K,T,E,N,R, and S | -250°C to 1767°C | - | - | 0.1°C | Thermometer | Contact | 50 Series | Thermocouples,Holster | FLUKE | ||
0061-1322-5 | FLUKE TI300+ | 0 | 226,508.80 | PB-Free | RoHS | Thermal Imager,IR Resolution 320x240 pixels, Engineered and Tested to Withstand a 2-Meter Drop, Measure up to 650 °C,Manual or Automatic Focus | -20°C to 650°C | ±2°C,±2% | 0.075°C | 640 x 480 Pixels,320 x 240 Pixels (IR Resolution) | Thermal Imager | Non Contact | Ti Series | Battery,Adapter,SD Card,Carry Case,Soft Case,USB | FLUKE | ||
0061-1484-1 | FLUKE VT08/APC | 9 | 27,288.80 | PB-Free | RoHS | Visual IR Thermometer, Frame Rate 9Hz, Temperature Measurement Range -20°C to 400°C, Infrared Resolution 120x90 Pixels | -20°C to 400°C | ±2°C,±2% | < 60mK | 120 x 90 Pixels (IR Resolution) | Visual IR | Non Contact | VT Series | Wrist Strap,Charger,Adapter,USB Cable | FLUKE | ||
0061-0481-0 | FLUKE54-2B | 2 | 21,788.00 | PB-Free | RoHS | Digital Thermometer Dual Input W/USB Record with Data Logging,Contact Type J,K,T,E,N,R, and S | -250°C to 1767°C | ±(0.05%+0.3°C) | - | 0.1°C | Thermometer | Contact | 50 Series | Thermocouples,Holster | FLUKE | ||
0061-1472-4 | FLUKE62-MAX/SNG | 19 | 4,986.64 | PB-Free | RoHS | IR Thermometer, Ingress Protection Rating IP54, Temperature Measurement Range -30°C to 500°C, Accuracy ±1.5°C, Distance to Spot Ratio 10:1 | -30°C to 500°C | ±1.5°C,±1.5% | - | 0.1°C,0.2°F | Thermometer | Non Contact | 60 Series | Instruction Sheet | FLUKE | ||
0061-0264-1 | FLUKE568 | 5 | 18,010.40 | PB-Free | RoHS | Infrared and Contact Thermometer Infrared Range -40°C to 800°C | -40°C to 800°C,-270°C to 1372°C | ±1°C,±1% | - | 0.1°C,0.1°F | Thermometer | Non Contact | 560 Series | Thermocouples,Carry Case,Software,USB Cable | FLUKE | ||
0061-1290-8 | FLUKE TI401-PRO9HZ | 1 | 300,743.10 | PB-Free | RoHS | Infrared Cameras,Auto Focus and Smart Lenses, Resolution 640x480 (307,200 pixels),Field of View 34 H x 24 V,Spatial Resolution 0.93 mRad | -20°C to 650°C | ±2°C,±2% | 0.075°C | 640 x 480 Pixels,640 x 480 Pixels (IR Resolution) | Thermal Imager | Non Contact | Ti Series | Carrying Case,Lens,USB,HDMI,Battery,micro SD Card | FLUKE | ||
0061-1483-9 | FLUKE VT06/APC | 3 | 20,432.80 | PB-Free | RoHS | Visual IR Thermometer, Frame Rate 9Hz, Temperature Measurement Range -20°C to 400°C, Infrared Resolution 120x90 Pixels | -20°C to 400°C | ±2°C,±2% | < 60mK | 120 x 90 Pixels (IR Resolution) | Visual IR | Non Contact | VT Series | Wrist Strap,Charger,Adapter,USB Cable | FLUKE | ||
0061-1451-6 | FLUKE PTI120-9HZ/400C | 3 | 41,776.80 | PB-Free | RoHS | Pocket Thermal Imager, 3.5 LCD Touchscreen Display Temperature Measurement Range of -20°C to 400°C 120x90 Pixel Infrared Resolution, Fluke Connect | -20°C to 400°C | ±2°C,±2% | 0.06°C | 320 x 240 Pixels,120 x 90 Pixels (IR Resolution) | Thermal Imager | Non Contact | PTi Series | Thermal imager,Soft case,Lanyard,USB cable | FLUKE | ||
0061-0263-8 | FLUKE561 | 13 | 10,485.60 | PB-Free | RoHS | Combined Infrared and Contact Thermometer IR and K-Type Contact | -40°C to 550°C | - | - | 0.1°C,0.1°F | Thermometer | Non Contact | 560 Series | Thermocouples,Carry Case | FLUKE | ||
0061-1118-6 | FLUKE64-MAX | 8 | 10,116.00 | PB-Free | RoHS | IR Thermometer,Temperature Range -30°C to 600°C Temperature Accuracy ±1°C Distance to Spot Ratio 20:1 | -30°C to 600°C | ±1°C,±1% | - | 0.1°C,0.2°F | Thermometer | Non Contact | 60 Series | Instruction Sheet | FLUKE | ||
0061-0377-9 | FLUKE566 | 3 | 16,968.00 | PB-Free | RoHS | Infrared and Contact Thermometer,Capture up to 20 Point of Data, Compatibility with K-Type Thermocouples | -40°C to 650°C | ±1°C,±1% | - | 0.1°C,0.1°F | Thermometer | Non Contact | 560 Series | Thermocouples,Carry Case,Manual | FLUKE | ||
0061-1427-9 | FLUKE TIS75+/9HZ | 1 | 213,580.45 | PB-Free | RoHS | Thermal Imager, Frame Rate 9Hz, IR Resolution 384x288 Pixels, Temperature Measurement Range -20°C to 550°C, Manual Focus, Fluke Connect | -20°C to 550°C | ±2°C,±2% | 0.04°C | 640 x 480 Pixels,384 x 288 Pixels (IR Resolution) | Thermal Imager | Non Contact | TiS Series | Adapter,Charger,Battery,USB,Strap,Case,SD Card | FLUKE | ||
0061-1539-1 | FLUKE TI480U-30HZ/AP | 2 | 501,066.19 | PB-Free | RoHS | Infrared Thermal Camera, Frame Rate 30Hz, IR Resolution 640x480, Temperature Range -20°C to 1200°C, Digital Zoom 1-10x, Auto/Manual Focus | -20°C to 1200°C | ±2°C,±2% | 0.05°C | 640 x 480 Pixels,640 x 480 Pixels (IR Resolution) | Thermal Imager | Non Contact | Ti Series | Charger,Battery,Carrying Case,HDMI Cable,USB Cable | FLUKE | ||
0061-0262-5 | FLUKE52-2 | 2 | 18,181.60 | PB-Free | RoHS | Dual Input Digital Thermometer, Support Thermocouple Types J,K,T,E Included Two Beaded Probe Thermocouples | -250°C to 1767°C | ±(0.05%+0.3°C) | - | 0.1°C,1°C | Thermometer | Contact | 50 Series | Thermocouples,Holster | FLUKE |