Picture | ES Part No. | Part No | Stock | Price | Datasheet | Pb Free | RoHS | Description | Temperature Measurement Range(MIN - MAX) | Measurement Accuracy | Thermal sensitivity(at Target Temperature) | Display Resolution | Instrument Type | Measurement Methods | Series | Include Accessories | Vendor |
0762-0003-6 | DT-9885 | 0 | 111,783.50 | PB-Free | RoHS | Thermal Imager,-20°C to 400°C,FOV 24.6 x 18.6, IR Resolution 384x288 Pixels,Focal Length 22mm, Thermal Sensitivity < 0.05°C at 30°C/50mK | -20°C to 400°C | ±2°C,±2%rdg | 0.06°C | 320 x 240 Pixels,384 x 288 Pixels (IR Resolution) | Thermal Imager | Non Contact | DT9885 | Carry Case,Battery,Manual,Lens cover,Lens | CEM | ||
0061-1328-7 | FLUKE TIS60+/9HZ | 2 | 148,197.68 | PB-Free | RoHS | Thermal Imager 9Hz,Resolution 320x240 Pixels, Measurement Range -20°C to +400°C, IR-Fusion Technology,Advance Manual Focus | -20°C to 400°C | ±2°C,±2% | 0.045°C | 320 x 240 Pixels,320 x 240 Pixels (IR Resolution) | Thermal Imager | Non Contact | TiS Series | Adapter,Charger,Battery,USB,Strap,Case,SD Card | FLUKE | ||
0762-0002-4 | DT-982 | 1 | 43,392.50 | PB-Free | RoHS | Thermal Imager,-20°C to 350°C,FOV 19 x 25, IR Resolution 120 x 160 Pixels,Focal Length 9mm, Thermal Sensitivity < 0.1°C at 30°C/100mK | -20°C to 350°C | ±2°C,±2%rdg | 0.1°C | 160 x 120 Pixels (IR Resolution) | Thermal Imager | Non Contact | DT980/982 | Battery,Charger,USB cable,HDMI Cable,User manual | CEM | ||
0061-1322-5 | FLUKE TI300+ | 0 | 226,508.80 | PB-Free | RoHS | Thermal Imager,IR Resolution 320x240 pixels, Engineered and Tested to Withstand a 2-Meter Drop, Measure up to 650 °C,Manual or Automatic Focus | -20°C to 650°C | ±2°C,±2% | 0.075°C | 640 x 480 Pixels,320 x 240 Pixels (IR Resolution) | Thermal Imager | Non Contact | Ti Series | Battery,Adapter,SD Card,Carry Case,Soft Case,USB | FLUKE | ||
0762-0025-6 | AI-321 | 2 | 31,500.00 | PB-Free | RoHS | Face Recognition Scanner, Support 3 Usage Modes: Access Control&Attendance for Company/School and Quick Screening, Measurement Range 32°C to 45°C | 32°C to 45°C | ±0.5°C | - | 1920 x 1080 Pixels (Camera Resolution) | Thermal Imager | Non Contact | AI321 | Screw,Interface Wiring,Power Adaptor | CEM | ||
0770-0129-3 | METREL-MD9930 | 0 | 78,800.00 | IR Thermal Camera for Predictive Maintenance IR Resolution 120 x 160 Pixel,50Hz Thermal Refresh Rate,Object Temperature Range -20°C to 350°C | -20°C to 350°C | ±2°C,±2%rdg | 0.1°C | 320 x 240 Pixels,160 x 120 Pixels (IR Resolution) | Thermal Imager | Non Contact | - | Carry Case,Adapter,Strap,Manual,USB,Micro SD Card | METREL | ||||
0061-1290-8 | FLUKE TI401-PRO9HZ | 1 | 300,743.10 | PB-Free | RoHS | Infrared Cameras,Auto Focus and Smart Lenses, Resolution 640x480 (307,200 pixels),Field of View 34 H x 24 V,Spatial Resolution 0.93 mRad | -20°C to 650°C | ±2°C,±2% | 0.075°C | 640 x 480 Pixels,640 x 480 Pixels (IR Resolution) | Thermal Imager | Non Contact | Ti Series | Carrying Case,Lens,USB,HDMI,Battery,micro SD Card | FLUKE | ||
0206-0040-4 | ETE-312-153-1 | 0 | 250,000.00 | EasyTrack3 Temperature Profiling System 6-Channel Input,Measurement -150°C to 500°C Type K Thermocouple | -150°C to 500°C | ±0.5°C | - | 0.1°C | Thermal Profiling Systems | Contact | EasyTrack3 | Thermocouple,Thermal Barrier,Manual,Battery | DATAPAQ | ||||
0206-0045-4 | RIS-033-219 | 1 | 325,000.00 | PB-Free | Reflow Tracker System,Including: DP5 6-Ch Narrow Data Logger-DP5662,6-Ch Narrow Thermal Barrier- TB2021,Six Type-K Thermocouples-PA0210 | -100°C to 1370°C | ±0.5°C | - | 0.1°C | Thermal Profiling Systems | Contact | Reflow Tracker | Thermocouple,Thermal Barrier,Software,Bag,Manual | DATAPAQ | |||
0206-0049-2 | RIS-338-220 | 0 | 420,000.00 | Reflow Tracker System,Including: DP5 12-Ch Narrow Data Logger-DP5612,Standard 12-Ch Thermal Barrier- TB2101 | -100°C to 1370°C | ±0.5°C | - | 0.1°C | Thermal Profiling Systems | Contact | Reflow Tracker | Thermal Barrier,Software,Bag,Manual | DATAPAQ | ||||
0206-0050-7 | ETE-313-153-1 | 1 | 260,000.00 | PB-Free | RoHS | EasyTrack3 Temperature Profiling System, Including 6Ch Data Logger-ET6063, Thermal Barrier-TB0263, Six Exposed Junction PTFE Thermocouples(Length 2m) | -150°C to 500°C | ±0.5°C | - | 0.1°C | Thermal Profiling Systems | Contact | EasyTrack3 | Thermocouple,Thermal Barrier,Software,Bag,Manual | DATAPAQ | ||
0206-0030-1 | ETP-313-153-2 | 0 | 338,000.00 | EasyTrack3 Temperature Profiling System, Including 6Ch Data Logger-ET6063, Thermal Barrier-TB0263, Clip Surface and Clip Air Thermocouple | -150°C to 500°C | ±0.5°C | - | 0.1°C | Thermal Profiling Systems | Contact | EasyTrack3 | Thermocouple,Thermal Barrier,Software,Bag,Manual | DATAPAQ | ||||
0206-0059-5 | RIS-147-219 | 1 | 300,000.00 | PB-Free | RoHS | Reflow Tracker System, Including: DP5 6-Ch Narrow Data Logger-DP5662, 6-Ch Low Height Narrow Thermal Barrier-TB2020, Six Type-K Thermocouples-PA0215 | -100°C to 1370°C | ±0.5°C | - | 0.1°C | Thermal Profiling Systems | Contact | Reflow Tracker | Thermocouple,Thermal Barrier,Software,Bag,Manual | DATAPAQ | ||
0206-0073-9 | OTU-022-217 | 1 | 320,000.00 | PB-Free | RoHS | Oven Thermal Profiling Systems, Including: DP5 6-Ch Data Logger-DP5660, Thermal Barrier-TB2003, Six Exposed Junction PTFE Thermocouples-PA0063 | -100°C to 1370°C | ±0.5°C | - | 0.1°C | Thermal Profiling Systems | Contact | - | Thermocouple,Thermal Barrier,Software,Bag,Manual | DATAPAQ | ||
0688-0018-2 | COMARK-N5001KIT/INT-DEMO | 1 | 14,750.00 | HACCP Auditor Kit, Log/Monitor/Manage Data, Full Graphic Display LCD, Temperature Profiling, DEMO | -200°C to 700°C,-200°C to 400°C | ±0.2°C | - | 0.1°C | Thermal Profiling Systems | Contact | - | - | COMARK |